The part of an insert job you never see
Once an insert is in and the surround is finished, the liner disappears from view. It runs up inside the chimney from the back of the unit to a cap on the roof, and for most Anaheim owners it is the line on the quote they understand least. It is also one of the larger lines. This post explains what the liner is for on an insert job, the kinds we fit, and the measurements that turn into the figure on your quote.
Our price list carries no single liner figure, because two chimneys on the same street can need very different lengths, sizes and types. Every liner we fit is priced in writing from measurements taken at the house.
Why an insert needs its own liner
An old clay flue in a brick chimney was built for an open fire: a big opening, lots of air and a fast, hot column of smoke. An insert burns in a closed box and sends a smaller, cooler stream of exhaust upward. Put that stream into the wide old flue and it slows and cools before reaching the top. Wood and pellet exhaust drops tar and soot on the way; gas exhaust leaves water.
A liner sized to the insert keeps the exhaust moving and warm all the way out. On gas inserts it also brings outside air down to the burner, either in a second pipe or in the space around the first one.
The liner types side by side
| Type | What it is | Where we use it |
|---|---|---|
| Flexible stainless | Corrugated stainless tube that bends to follow the flue | Most wood and pellet inserts, and the exhaust side of many gas inserts |
| Rigid stainless | Straight stainless sections joined end to end | Straight, unobstructed flues where a smooth wall is worth having |
| Twin flexible for gas | One pipe for exhaust, one for fresh air | Sealed gas inserts that draw air from outside |
| Pellet vent | Small diameter stainless pipe, often with an adapter at the stove | Pellet inserts |
| Poured in place | A cement mix formed inside the old flue around a removable form | Old chimneys with badly broken tile, where the masonry needs the support |
Most insert jobs in Anaheim use a flexible stainless liner. The poured option is less common and suits a different problem: a chimney where the old tile is in poor shape and the owner wants a masonry lining again.
The measurements that set the price
When we write a liner quote, these are the numbers on the page:
Length. Measured from the insert's outlet to the top of the chimney, plus what is needed at each end. A single storey ranch in central Anaheim needs a fairly short run; a two storey house with a tall stack needs a good deal more.
Diameter. Set by the insert's outlet and the maker's manual, then checked against the inside of the old flue. A flue with a narrow spot can force a slimmer or oval liner, which in turn limits the inserts that can be used.
Insulation. Some inserts and some chimneys call for an insulated liner, because the clearance between the brick and the house framing is tight or because the maker requires it. Insulation adds material and labour.
The path. A straight flue lets a liner drop in from the top. Offsets, a damper frame that will not let the liner pass, or a tight smoke shelf add time and sometimes cutting.
The top. Every liner ends in a cap, and the old flue around it is sealed with a top plate. If the top slab is cracked, that repair is listed on its own line.
The chimney itself. A liner does not hold up loose brick. If the stack needs repointing, bracing or a rebuild above the roof, that comes first and is priced separately.
If you want a liner priced for your own chimney, ask for a liner quote and tell us which insert you have chosen or are considering, whether the house has one storey or two, and the fuel. The liner depends on the unit, so knowing it early makes the quote firmer.
How the liner fits into the whole job
On an insert job, the liner is part of a single quote along with the unit, the gas or power connection and any hearth or mantel work. For a gas insert, our listed price of $2,800 to $5,650 already includes the venting for a normal chimney. For wood and pellet units, the liner is a line of its own on a written quote.
Owners also ask us for liners without an insert: an old gas furnace or water heater vent, a cracked flue on a fireplace that will stay open, or a chimney that failed its inspection. Those jobs are covered on our chimney liner installation page.
Questions owners ask
Will a liner fix a cracked flue? For venting, yes: the exhaust travels in the new liner, not the old tile. It does not fix outer brick or a cracked top slab, which are separate repairs.
Can a liner go in a factory built fireplace? Usually not. Metal fireplaces have their own listed pipe, and any insert has to be one the maker allows.
Does the liner need cleaning? On wood and pellet units, yes, on a schedule set by how much you burn. On gas units we look at it during the yearly service.
Can you reuse a liner from an old insert? Only if it is the right size for the new unit and passes a camera check. In practice most are replaced along with the insert.
Start with a measurement
A liner price means little until someone has measured the flue. Our inspection before an insert post explains that visit. If you are in Anaheim, Riverside or one of the cities nearby, send us a note through the contact page and we will come out with the tape and the camera.
From Reading to a Written Plan
On one visit Channing Chimney Services sizes the opening, checks any label plate, films the flue and then sends the upgrades that fit, priced in columns. Requests come from Anaheim, Brea, Orange, Riverside and the other cities on our list.