Local weather and fireplace inspection in Riverside
Wood is banned on forecast No-Burn days from November through February under Rule 445, anywhere below 3,000 feet, so our insert sheet here always carries a gas column. Chino Hills' 2008 shaking was strong in this city, hence a flue test first. On this job our list includes firebrick and refractory panels examined for cracks, damper opened, closed and checked for warping, and hearth extension measured against the opening, and anything that would shape a future insert or liner is added to the notes.